Ocorrência
No módulo TOTVS PDV SQLite, ao realizar o recebimento de carga, erro é apresentado:
THREAD ERROR ([3828], CAIXA, PDV01) 11/07/2020 09:59:52
Alias does not exist TRB on LJCINITIALLOADLOADER:IMPORTPARTIAL(LOJA1144.PRW) 10/06/2020 17:43:29 line : 739
[TOTVS build: 7.00.170117A-20200331]
Called from LJCINITIALLOADLOADER:IMPORT(LOJA1144.PRW) 10/06/2020 17:43:29 line : 260
Called from LOADPROCESS(LOJA1159.PRW) 24/01/2020 15:02:40 line : 681
Called from LJCINITIALLOADLOADERWIZARD:STARTLOAD(LOJA1145.PRW) 03/06/2020 08:31:58 line : 613
Called from LJCINITIALLOADLOADERWIZARD:LOADSTART(LOJA1145.PRW) 03/06/2020 08:31:58 line : 443
Called from LJCINITIALLOADLOADERWIZARD:BUTTONCLICK(LOJA1145.PRW) 03/06/2020 08:31:58 line : 341
Called from { || SELF:BUTTONCLICK(SELF:OBTNSTARTLOAD)}(LOJA1145.PRW) 03/06/2020 08:31:58 line : 288
Ambiente
Microsiga Protheus – SIGAFRT/TOTVS PDV – A partir da versão 12.1.25
Causa
Esse incidente ocorre, pois a parametrização do sistema está incorreta para o recebimento de Carga
Solução
Para solucionar essa ocorrência, realize os seguintes passos:
1. Tratando-se de SQLite, onde dicionário é migrado para o banco de dados, parâmetros de carga devem ser configurados como apontado abaixo:
- MV_LJGECSV = 2 (Tipos de arquivos de geração de carga: 0 -DBF/CTREE, 1 - DBF/CTREE e CSV, 2 - CSV.)
- MV_LJILDRV = CSV (Define o driver para geração da carga. Caso não informado assume a configuração do sistema.)
Importante:
Arquitetura de ambiente TOTVS PDV SQLite só é compatível com ambiente Retaguarda com Dicionário Migrado para o Banco de Dados, caso contrário devemos utilizar ambiente Ctree em Retaguarda e TOTVS PDV.
Saiba Mais:
MP - TOTVS PDV - Parâmetros MV_LJGECSV e MV_LJILDRV
MP - TOTVS PDV - Arquitetura dos Ambientes TOTVS PDV e Retaguarda a partir da release 12.1.23