Ocorrência
No módulo Controle de lojas, ao tentar incluir um novo cadastro na rotina Codigo de Administradores SITEF é apresentada um error log.
THREAD ERROR ([78264], Jose Eustaquio, JOSELADEIRA) 01/06/2018 10:09:44
DB error (Insert): -37 File: SLI010 - Error : 1 - ORA-00001: unique constraint (ATKN9D_TESTE.SLI010_UNQ) violated
( From tISAMFile::Write )
Thread ID [39424] User [CAIXA18] IO [9591] Tables [29] MaxTables [29] Comment [LOJA350 - TCPIP - ThreadID(78264)] SP [ ] Traced [No] SQLReplay [No] InTran [Yes] DBEnv [ORACLE/ATKN9D_TESTE] DBThread [(SID 1026,23103,1)] Started [01/06/2018 10:08:20] IP [127.0.0.1:30001] IDLE [ ] InTransact [0 s.] Memory [1006208] Running [ROP_WRITE] RCV [140312] SND [871023] TCBuild [20171117-20180412]
INSERT INTO SLI010(LI_FILIAL,LI_ESTACAO,LI_TIPO,LI_USUARIO,LI_DATA,LI_HORA,LI_MSG,R_E_C_N_O_) VALUES ( :1,:2,:3,:4,:5,:6,:7,:8)
Ambiente
Microsiga Protheus – SIGALOJA – TOTVS PDV - SIGAFRT - A partir da release 12.1.17.
Causa
Inconsistência no dicionario de dados.
Solução
Para solucionar essa ocorrência, realize os seguintes passos:
1. Antes de qualquer alteração ou atualização é necessário sempre efetuar backup,
2. Acesse via APSDU/System/SX3,
3. Altere o conteúdo do X3_WHEN dos campos MDE_ARQIMP, MDE_ARQPRO e MDE_ARQINC
De: | FA910VLD(M->MDE_TIPO = "RD") |
Para: | M->MDE_TIPO = "RD" |
4. Essa correção é um paliativo, pois como é uma inconsistência de dicionario de dados a correção será liberada na próxima release, prevista para inicio de Agosto.