//DOCUMENTO COMPLEMENTO ICMS ou IPI
#Include "Protheus.ch"
#Include "RwMake.ch"
#Include "TbiConn.ch"
User Function EXEC103()
Local aCab := {}
Local aItem := {}
Local aItens := {}
Local nOpc := 3
Local nI := 0
Local nX := 0
Local nReg := 1
Local cInicio := Time()
Private lMsErroAuto := .F.
Private lMsHelpAuto := .T.
PREPARE ENVIRONMENT EMPRESA "01" FILIAL "1001" MODULO "COM" FUNNAME "MATA103"
For nI := 1 To nReg
lMsErroAuto := .F.
aCab := {}
aItem := {}
aItens := {}
If nOpc == 3
aadd(aCab,{"F1_SERIE" ,"1 " ,NIL})
aadd(aCab,{"F1_FORNECE" ,"001 " ,NIL})
aadd(aCab,{"F1_LOJA" ,"01" ,NIL})
aadd(aCab,{"F1_EMISSAO" ,DDATABASE ,NIL})
aadd(aCab,{"F1_DTDIGIT" ,DDATABASE ,NIL})
aadd(aCab,{"F1_TIPO" ,"I" ,NIL}) // I - Complemento ICMS / P - Complemento IPI
aadd(aCab,{"F1_FORMUL" ,"S" ,NIL})
aadd(aCab,{"F1_ESPECIE" ,"NFE" ,NIL})
aadd(aCab,{"F1_COND" ,"001" ,NIL})
aadd(aCab,{"F1_DESPESA" , 0 , Nil})
aadd(aCab,{"F1_DESCONT" , 0 , Nil})
aadd(aCab,{"F1_SEGURO" , 0 , Nil})
aadd(aCab,{"F1_FRETE" , 0 , Nil})
aadd(aCab,{"F1_MOEDA" , 1 , Nil})
aadd(aCab,{"F1_TXMOEDA" , 1 , Nil})
aadd(aCab,{"F1_STATUS" , "A" , Nil})
aadd(aCab,{"F1_VOLUME1",0, Nil})
aadd(aCab,{"F1_PLIQUI",0, Nil})
aadd(aCab,{"F1_PBRUTO",0, Nil})
For nX := 1 To 1
cProd1 := "0001 "
aItem := {}
aadd(aItem,{"D1_ITEM" ,"0001" ,NIL})
aadd(aItem,{"D1_COD" ,PadR(cProd1,TamSx3("D1_COD")[1]) ,NIL})
aadd(aItem,{"D1_UM" ,"UN" ,NIL})
aadd(aItem,{"D1_LOCAL" ,"01" ,NIL})
aadd(aItem,{"D1_VUNIT" ,10 ,NIL})
aadd(aItem,{"D1_TOTAL" ,100 ,NIL})
aadd(aItem,{"D1_NFORI" ,"000132 ",NIL})
aadd(aItem,{"D1_SERIORI" ,"1 " ,NIL})
aadd(aItem,{"D1_ITEMORI" ,"01" ,NIL})
aadd(aItem,{"D1_TES" ,"066" ,NIL})
aAdd(aItens,aItem)
Next nX
MSExecAuto({|x,y,z,a| MATA103(x,y,z)},aCab,aItens,nOpc)
If !lMsErroAuto
ConOut(" NF_incluída)
Else
MostraErro()
ConOut("Erro na inclusao!")
Exit
EndIf
Next nI
Conout("Inicio: " + cInicio)
ConOut("Fim: " + Time())
RESET ENVIRONMENT
Return