Tiempo aproximado de lectura 00:03:00 min
Ocurrencia
Al realizar el proceso de migración a la versión 12.1.2310 se presenta el error log;
THREAD ERROR ([12328], USER, CMXTOTVSUPGRADE) 12/10/2024 10:01:33
XX7000: SetOrder - Index not found. on UPDOPENSX(APUPD020.PRW) 18/09/2024 13:41:02 line : 1130
[TOTVS build: 7.00.210324P-20240902]
Called from {|| UPDOPENSX( SM0->M0_CODIGO, NIL, .F. ) }(APUPD010.PRW) 18/09/2024 13:41:02 line : 68
Called from {|| EVAL(BACTION, OSAY), ODLGSVG:END() }(FWMSGRUN.PRW) 18/09/2024 13:41:02 line : 100
Called from ::FWSTYLEDDIALOG:ACTIVATE
Called from FWMSGRUN(FWMSGRUN.PRW) 18/09/2024 13:41:02 line : 100
Called from UPDSHOWLOG(APUPD010.PRW) 18/09/2024 13:41:02 line : 68
Called from {|| UPDSHOWLOG()}(UPDDISTR.PRW) 18/09/2024 13:41:02 line : 774
Called from ::MSDIALOG:ACTIVATE
Called from FWDIALOGMODAL:ACTIVATE(FWDIALOGMODAL.PRW) 18/09/2024 13:41:02 line : 468
Called from APWIZARD:ACTIVATE(APWIZARD.PRW) 18/09/2024 13:41:03 line : 345
Called from APUPDATE(UPDDISTR.PRW) 18/09/2024 13:41:02 line : 796
Called from {|| ( OAPP:LFLAT:= .F. , APUPDATE(PARAMETER01), FINAL(FWI18NLANG("UPDDISTR","STR0500",196)) )}(UPDDISTR.PRW) 18/09/2024 13:41:02 line : 77
Called from {|| ODESKTOP:ACTIVATE(), ODESKTOP:HIDELOGIN(), ( OAPP:OMSGBAR := ODESKTOP:GETMSGBAR() ), SELF:ADDMSGITEM(), EVAL(SELF:BMAININIT,ODESKTOP)}(FWAPP.PRW) 18/09/2024 13:41:05 line : 734
Called from ::TWINDOW:ACTIVATE
Called from MSAPP:ACTIVATE(FWAPP.PRW) 18/09/2024 13:41:05 line : 790
Called from UPDDISTR(UPDDISTR.PRW) 18/09/2024 13:41:02 line : 82
Entorno
Cross Segmentos - TOTVS BackOffice (Línea Protheus) - MI - Configurador (SIGACFG) - versión 12.1.2310
Solución
Para solucionar esa ocurrencia, realice los siguientes pasos:
- Realice un respaldo de las tablas XX6000 y XX7000.
- Realice un drop de las tablas XX6000 y XX7000;
- Reinicie todos los servicios e intente acceder al sistema.
- Posteriormente ejecute nuevamente el UPDDISTR y valide que el error reportado no se presente.
0 Comentarios